How Low Temperatures Impact Dye Penetrant Testing

How Low Temperatures Impact Dye Penetrant Testing

The operating temperature range for penetrant inspection as specified in ASTM E1417 Standard Practice for Liquid Penetrant Testing is 40°F to 125°F (4°C to 52°C), but how is the penetrant inspection affected at temperatures below 40°F (4°C) and can the inspection process be adjusted to achieve acceptable results?

To answer these questions, we evaluated SKC-S cleaner/removerSKL-SP2 solvent removable dye penetrant and SKD-S2 non-aqueous developer at a range of temperatures in order to figure out what NDT inspectors can expect when using these, or similar quality dye penetrant products when inspecting at lower temperatures

Cleaning at lower temperatures

At lower temperatures in the range of 32°F – 50°F (0°C – 10°C), the solvent cleaner will take longer to dry.

We used 75°F (24°C) as our ambient, standard operating temperature, and observed how decreasing temperatures impacted how quickly the solvent cleaner dried. Below are our suggested drying time for solvent-based cleaner/removers at lower temperatures.

Read more